×

Productos

    Abrir menu

    HIPLUS AIRE ACONDICIONADO, S.L.

    C. Masía Torrents, 2
    08800 VILANOVA I LA GELTRÚ (Barcelona)

    REQUEST A QUOTE/INFORMATION
    X
    Visualizar en modo Listado Visualizar en modo Cuadrícula
    8 productos.
    801 - Water chiller, axial fan, Mini Krono 2 - Cooling only

    General The chiller/heat pumps air-water EWXA/EWXBA are compact units designed for outside installation, on flat roofs, terraces or the ground. They are supplied with the refrigerant charge ready for installation. These units have been manufactured under strict quality control throughout the entire process. Sheet structure The structure of this equipment is resistant to outside weather conditons, of galvanized steel. It provides an excelent coating in corners and edges. The design has been concived for an easy maintenance. The finished assembly is in colour RAL 1013. Refrigerant circuit - Outdoor coils with copper piping and aluminium fins. - ACR copper refrigerant lines. - Filter driers in liquid lines. - Reversible 4-way valves. - Double expansion system. - Suction accumulators. - Non-return valves. Compressors This serie of units incorporate a scroll compressor. This includes internal thermal protection, together with crankcase heater to protect this against the refrigerant liquid slugging during start-up. Outdoor coil These coils are constructed from weld-free 3/8 copper piping, which is expanded in aluminium fins. Water-refrigerant heat exchanger Stainless steel plates. They are fully insulated and incorporate an electrical heater to prevent freezing, when the machine is shutdown. Motor-driven fans These are completely closed off for outside weather conditions, with permanent lubrication. They are formed from aluminium blades designed to produce low noise levels, which are inserted into the exterior rotor of to high-efficiency motor, with IP-54 protection and class F insulation. They are fitted with internal thermal protection sensors, together with an exterior safety grille. Expansion devices The unit is equipped with thermostatic expansion valves with MOP. One in the inlet of plate heat exchanger for functioning in refrigeration mode. The expansion in the outdoor coil, when necessary (functioning in heating mode), it is done through orifice (nozzle). Protections - High pressure pressostat with automatic reset.. - Compressor crankcase heater. - Antifreeze thermostat for water. - Timings for start-up (180 seg.). - Timings of compressor (30 segundos) - Main switch. - Pressure transducers. - Phases sequence relay (scroll compressor). - Temperature regulation probes. - Selecting cooling-heating. - Defrost system. - Second Setpoint Electronic control The microprocessor manages the machine functioning and its alarms. Through probes it controls continously water temperature. Optionals - Magnetothermic switches. - Differential pressotat of waterflow detection. - Condensation control. - Evaporation control (as a special order). - Cmpressor cover. - Hydronic kit Heat pump + expansion vessel Water pump + expansion vessel+ tank Electrical supporting resistance - Compressor soft-start Power supply 400.III.+N.50 Hz ~. 230.III.50 Hz ~.

    801 - Water chiller, axial fan, Mini Krono 2 - Heat pump

    General The chiller/heat pumps air-water EWXA/EWXBA are compact units designed for outside installation, on flat roofs, terraces or the ground. They are supplied with the refrigerant charge ready for installation. These units have been manufactured under strict quality control throughout the entire process. Sheet structure The structure of this equipment is resistant to outside weather conditons, of galvanized steel. It provides an excelent coating in corners and edges. The design has been concived for an easy maintenance. The finished assembly is in colour RAL 1013. Refrigerant circuit - Outdoor coils with copper piping and aluminium fins. - ACR copper refrigerant lines. - Filter driers in liquid lines. - Reversible 4-way valves. - Double expansion system. - Suction accumulators. - Non-return valves. Compressors This serie of units incorporate a scroll compressor. This includes internal thermal protection, together with crankcase heater to protect this against the refrigerant liquid slugging during start-up. Outdoor coil These coils are constructed from weld-free 3/8 copper piping, which is expanded in aluminium fins. Water-refrigerant heat exchanger Stainless steel plates. They are fully insulated and incorporate an electrical heater to prevent freezing, when the machine is shutdown. Motor-driven fans These are completely closed off for outside weather conditions, with permanent lubrication. They are formed from aluminium blades designed to produce low noise levels, which are inserted into the exterior rotor of to high-efficiency motor, with IP-54 protection and class F insulation. They are fitted with internal thermal protection sensors, together with an exterior safety grille. Expansion devices The unit is equipped with thermostatic expansion valves with MOP. One in the inlet of plate heat exchanger for functioning in refrigeration mode. The expansion in the outdoor coil, when necessary (functioning in heating mode), it is done through orifice (nozzle). Protections - High pressure pressostat with automatic reset.. - Compressor crankcase heater. - Antifreeze thermostat for water. - Timings for start-up (180 seg.). - Timings of compressor (30 segundos) - Main switch. - Pressure transducers. - Phases sequence relay (scroll compressor). - Temperature regulation probes. - Selecting cooling-heating. - Defrost system. - Second Setpoint Electronic control The microprocessor manages the machine functioning and its alarms. Through probes it controls continously water temperature. Optionals - Magnetothermic switches. - Differential pressotat of waterflow detection. - Condensation control. - Evaporation control (as a special order). - Cmpressor cover. - Hydronic kit Heat pump + expansion vessel Water pump + expansion vessel+ tank Electrical supporting resistance - Compressor soft-start Power supply 400.III.+N.50 Hz ~. 230.III.50 Hz ~.

    1001 - Water chiller, axial fan, Mini Krono 2 - Cooling only

    General The chiller/heat pumps air-water EWXA/EWXBA are compact units designed for outside installation, on flat roofs, terraces or the ground. They are supplied with the refrigerant charge ready for installation. These units have been manufactured under strict quality control throughout the entire process. Sheet structure The structure of this equipment is resistant to outside weather conditons, of galvanized steel. It provides an excelent coating in corners and edges. The design has been concived for an easy maintenance. The finished assembly is in colour RAL 1013. Refrigerant circuit - Outdoor coils with copper piping and aluminium fins. - ACR copper refrigerant lines. - Filter driers in liquid lines. - Reversible 4-way valves. - Double expansion system. - Suction accumulators. - Non-return valves. Compressors This serie of units incorporate a scroll compressor. This includes internal thermal protection, together with crankcase heater to protect this against the refrigerant liquid slugging during start-up. Outdoor coil These coils are constructed from weld-free 3/8 copper piping, which is expanded in aluminium fins. Water-refrigerant heat exchanger Stainless steel plates. They are fully insulated and incorporate an electrical heater to prevent freezing, when the machine is shutdown. Motor-driven fans These are completely closed off for outside weather conditions, with permanent lubrication. They are formed from aluminium blades designed to produce low noise levels, which are inserted into the exterior rotor of to high-efficiency motor, with IP-54 protection and class F insulation. They are fitted with internal thermal protection sensors, together with an exterior safety grille. Expansion devices The unit is equipped with thermostatic expansion valves with MOP. One in the inlet of plate heat exchanger for functioning in refrigeration mode. The expansion in the outdoor coil, when necessary (functioning in heating mode), it is done through orifice (nozzle). Protections - High pressure pressostat with automatic reset.. - Compressor crankcase heater. - Antifreeze thermostat for water. - Timings for start-up (180 seg.). - Timings of compressor (30 segundos) - Main switch. - Pressure transducers. - Phases sequence relay (scroll compressor). - Temperature regulation probes. - Selecting cooling-heating. - Defrost system. - Second Setpoint Electronic control The microprocessor manages the machine functioning and its alarms. Through probes it controls continously water temperature. Optionals - Magnetothermic switches. - Differential pressotat of waterflow detection. - Condensation control. - Evaporation control (as a special order). - Cmpressor cover. - Hydronic kit Heat pump + expansion vessel Water pump + expansion vessel+ tank Electrical supporting resistance - Compressor soft-start Power supply 400.III.+N.50 Hz ~. 230.III.50 Hz ~.

    1001 - Water chiller, axial fan, Mini Krono 2 - Heat pump

    General The chiller/heat pumps air-water EWXA/EWXBA are compact units designed for outside installation, on flat roofs, terraces or the ground. They are supplied with the refrigerant charge ready for installation. These units have been manufactured under strict quality control throughout the entire process. Sheet structure The structure of this equipment is resistant to outside weather conditons, of galvanized steel. It provides an excelent coating in corners and edges. The design has been concived for an easy maintenance. The finished assembly is in colour RAL 1013. Refrigerant circuit - Outdoor coils with copper piping and aluminium fins. - ACR copper refrigerant lines. - Filter driers in liquid lines. - Reversible 4-way valves. - Double expansion system. - Suction accumulators. - Non-return valves. Compressors This serie of units incorporate a scroll compressor. This includes internal thermal protection, together with crankcase heater to protect this against the refrigerant liquid slugging during start-up. Outdoor coil These coils are constructed from weld-free 3/8 copper piping, which is expanded in aluminium fins. Water-refrigerant heat exchanger Stainless steel plates. They are fully insulated and incorporate an electrical heater to prevent freezing, when the machine is shutdown. Motor-driven fans These are completely closed off for outside weather conditions, with permanent lubrication. They are formed from aluminium blades designed to produce low noise levels, which are inserted into the exterior rotor of to high-efficiency motor, with IP-54 protection and class F insulation. They are fitted with internal thermal protection sensors, together with an exterior safety grille. Expansion devices The unit is equipped with thermostatic expansion valves with MOP. One in the inlet of plate heat exchanger for functioning in refrigeration mode. The expansion in the outdoor coil, when necessary (functioning in heating mode), it is done through orifice (nozzle). Protections - High pressure pressostat with automatic reset.. - Compressor crankcase heater. - Antifreeze thermostat for water. - Timings for start-up (180 seg.). - Timings of compressor (30 segundos) - Main switch. - Pressure transducers. - Phases sequence relay (scroll compressor). - Temperature regulation probes. - Selecting cooling-heating. - Defrost system. - Second Setpoint Electronic control The microprocessor manages the machine functioning and its alarms. Through probes it controls continously water temperature. Optionals - Magnetothermic switches. - Differential pressotat of waterflow detection. - Condensation control. - Evaporation control (as a special order). - Cmpressor cover. - Hydronic kit Heat pump + expansion vessel Water pump + expansion vessel+ tank Electrical supporting resistance - Compressor soft-start Power supply 400.III.+N.50 Hz ~. 230.III.50 Hz ~.

    1201 - Water chiller, axial fan, Mini Krono 2 - Cooling only

    General The chiller/heat pumps air-water EWXA/EWXBA are compact units designed for outside installation, on flat roofs, terraces or the ground. They are supplied with the refrigerant charge ready for installation. These units have been manufactured under strict quality control throughout the entire process. Sheet structure The structure of this equipment is resistant to outside weather conditons, of galvanized steel. It provides an excelent coating in corners and edges. The design has been concived for an easy maintenance. The finished assembly is in colour RAL 1013. Refrigerant circuit - Outdoor coils with copper piping and aluminium fins. - ACR copper refrigerant lines. - Filter driers in liquid lines. - Reversible 4-way valves. - Double expansion system. - Suction accumulators. - Non-return valves. Compressors This serie of units incorporate a scroll compressor. This includes internal thermal protection, together with crankcase heater to protect this against the refrigerant liquid slugging during start-up. Outdoor coil These coils are constructed from weld-free 3/8 copper piping, which is expanded in aluminium fins. Water-refrigerant heat exchanger Stainless steel plates. They are fully insulated and incorporate an electrical heater to prevent freezing, when the machine is shutdown. Motor-driven fans These are completely closed off for outside weather conditions, with permanent lubrication. They are formed from aluminium blades designed to produce low noise levels, which are inserted into the exterior rotor of to high-efficiency motor, with IP-54 protection and class F insulation. They are fitted with internal thermal protection sensors, together with an exterior safety grille. Expansion devices The unit is equipped with thermostatic expansion valves with MOP. One in the inlet of plate heat exchanger for functioning in refrigeration mode. The expansion in the outdoor coil, when necessary (functioning in heating mode), it is done through orifice (nozzle). Protections - High pressure pressostat with automatic reset.. - Compressor crankcase heater. - Antifreeze thermostat for water. - Timings for start-up (180 seg.). - Timings of compressor (30 segundos) - Main switch. - Pressure transducers. - Phases sequence relay (scroll compressor). - Temperature regulation probes. - Selecting cooling-heating. - Defrost system. - Second Setpoint Electronic control The microprocessor manages the machine functioning and its alarms. Through probes it controls continously water temperature. Optionals - Magnetothermic switches. - Differential pressotat of waterflow detection. - Condensation control. - Evaporation control (as a special order). - Cmpressor cover. - Hydronic kit Heat pump + expansion vessel Water pump + expansion vessel+ tank Electrical supporting resistance - Compressor soft-start Power supply 400.III.+N.50 Hz ~. 230.III.50 Hz ~.

    1201 - Water chiller, axial fan, Mini Krono 2 - Heat pump

    General The chiller/heat pumps air-water EWXA/EWXBA are compact units designed for outside installation, on flat roofs, terraces or the ground. They are supplied with the refrigerant charge ready for installation. These units have been manufactured under strict quality control throughout the entire process. Sheet structure The structure of this equipment is resistant to outside weather conditons, of galvanized steel. It provides an excelent coating in corners and edges. The design has been concived for an easy maintenance. The finished assembly is in colour RAL 1013. Refrigerant circuit - Outdoor coils with copper piping and aluminium fins. - ACR copper refrigerant lines. - Filter driers in liquid lines. - Reversible 4-way valves. - Double expansion system. - Suction accumulators. - Non-return valves. Compressors This serie of units incorporate a scroll compressor. This includes internal thermal protection, together with crankcase heater to protect this against the refrigerant liquid slugging during start-up. Outdoor coil These coils are constructed from weld-free 3/8 copper piping, which is expanded in aluminium fins. Water-refrigerant heat exchanger Stainless steel plates. They are fully insulated and incorporate an electrical heater to prevent freezing, when the machine is shutdown. Motor-driven fans These are completely closed off for outside weather conditions, with permanent lubrication. They are formed from aluminium blades designed to produce low noise levels, which are inserted into the exterior rotor of to high-efficiency motor, with IP-54 protection and class F insulation. They are fitted with internal thermal protection sensors, together with an exterior safety grille. Expansion devices The unit is equipped with thermostatic expansion valves with MOP. One in the inlet of plate heat exchanger for functioning in refrigeration mode. The expansion in the outdoor coil, when necessary (functioning in heating mode), it is done through orifice (nozzle). Protections - High pressure pressostat with automatic reset.. - Compressor crankcase heater. - Antifreeze thermostat for water. - Timings for start-up (180 seg.). - Timings of compressor (30 segundos) - Main switch. - Pressure transducers. - Phases sequence relay (scroll compressor). - Temperature regulation probes. - Selecting cooling-heating. - Defrost system. - Second Setpoint Electronic control The microprocessor manages the machine functioning and its alarms. Through probes it controls continously water temperature. Optionals - Magnetothermic switches. - Differential pressotat of waterflow detection. - Condensation control. - Evaporation control (as a special order). - Cmpressor cover. - Hydronic kit Heat pump + expansion vessel Water pump + expansion vessel+ tank Electrical supporting resistance - Compressor soft-start Power supply 400.III.+N.50 Hz ~. 230.III.50 Hz ~.

    1501 - Water chiller, axial fan, Mini Krono 2 - Cooling only

    General The chiller/heat pumps air-water EWXA/EWXBA are compact units designed for outside installation, on flat roofs, terraces or the ground. They are supplied with the refrigerant charge ready for installation. These units have been manufactured under strict quality control throughout the entire process. Sheet structure The structure of this equipment is resistant to outside weather conditons, of galvanized steel. It provides an excelent coating in corners and edges. The design has been concived for an easy maintenance. The finished assembly is in colour RAL 1013. Refrigerant circuit - Outdoor coils with copper piping and aluminium fins. - ACR copper refrigerant lines. - Filter driers in liquid lines. - Reversible 4-way valves. - Double expansion system. - Suction accumulators. - Non-return valves. Compressors This serie of units incorporate a scroll compressor. This includes internal thermal protection, together with crankcase heater to protect this against the refrigerant liquid slugging during start-up. Outdoor coil These coils are constructed from weld-free 3/8 copper piping, which is expanded in aluminium fins. Water-refrigerant heat exchanger Stainless steel plates. They are fully insulated and incorporate an electrical heater to prevent freezing, when the machine is shutdown. Motor-driven fans These are completely closed off for outside weather conditions, with permanent lubrication. They are formed from aluminium blades designed to produce low noise levels, which are inserted into the exterior rotor of to high-efficiency motor, with IP-54 protection and class F insulation. They are fitted with internal thermal protection sensors, together with an exterior safety grille. Expansion devices The unit is equipped with thermostatic expansion valves with MOP. One in the inlet of plate heat exchanger for functioning in refrigeration mode. The expansion in the outdoor coil, when necessary (functioning in heating mode), it is done through orifice (nozzle). Protections - High pressure pressostat with automatic reset.. - Compressor crankcase heater. - Antifreeze thermostat for water. - Timings for start-up (180 seg.). - Timings of compressor (30 segundos) - Main switch. - Pressure transducers. - Phases sequence relay (scroll compressor). - Temperature regulation probes. - Selecting cooling-heating. - Defrost system. - Second Setpoint Electronic control The microprocessor manages the machine functioning and its alarms. Through probes it controls continously water temperature. Optionals - Magnetothermic switches. - Differential pressotat of waterflow detection. - Condensation control. - Evaporation control (as a special order). - Cmpressor cover. - Hydronic kit Heat pump + expansion vessel Water pump + expansion vessel+ tank Electrical supporting resistance - Compressor soft-start Power supply 400.III.+N.50 Hz ~. 230.III.50 Hz ~.

    1501 - Water chiller, axial fan, Mini Krono 2 - Heat pump

    General The chiller/heat pumps air-water EWXA/EWXBA are compact units designed for outside installation, on flat roofs, terraces or the ground. They are supplied with the refrigerant charge ready for installation. These units have been manufactured under strict quality control throughout the entire process. Sheet structure The structure of this equipment is resistant to outside weather conditons, of galvanized steel. It provides an excelent coating in corners and edges. The design has been concived for an easy maintenance. The finished assembly is in colour RAL 1013. Refrigerant circuit - Outdoor coils with copper piping and aluminium fins. - ACR copper refrigerant lines. - Filter driers in liquid lines. - Reversible 4-way valves. - Double expansion system. - Suction accumulators. - Non-return valves. Compressors This serie of units incorporate a scroll compressor. This includes internal thermal protection, together with crankcase heater to protect this against the refrigerant liquid slugging during start-up. Outdoor coil These coils are constructed from weld-free 3/8 copper piping, which is expanded in aluminium fins. Water-refrigerant heat exchanger Stainless steel plates. They are fully insulated and incorporate an electrical heater to prevent freezing, when the machine is shutdown. Motor-driven fans These are completely closed off for outside weather conditions, with permanent lubrication. They are formed from aluminium blades designed to produce low noise levels, which are inserted into the exterior rotor of to high-efficiency motor, with IP-54 protection and class F insulation. They are fitted with internal thermal protection sensors, together with an exterior safety grille. Expansion devices The unit is equipped with thermostatic expansion valves with MOP. One in the inlet of plate heat exchanger for functioning in refrigeration mode. The expansion in the outdoor coil, when necessary (functioning in heating mode), it is done through orifice (nozzle). Protections - High pressure pressostat with automatic reset.. - Compressor crankcase heater. - Antifreeze thermostat for water. - Timings for start-up (180 seg.). - Timings of compressor (30 segundos) - Main switch. - Pressure transducers. - Phases sequence relay (scroll compressor). - Temperature regulation probes. - Selecting cooling-heating. - Defrost system. - Second Setpoint Electronic control The microprocessor manages the machine functioning and its alarms. Through probes it controls continously water temperature. Optionals - Magnetothermic switches. - Differential pressotat of waterflow detection. - Condensation control. - Evaporation control (as a special order). - Cmpressor cover. - Hydronic kit Heat pump + expansion vessel Water pump + expansion vessel+ tank Electrical supporting resistance - Compressor soft-start Power supply 400.III.+N.50 Hz ~. 230.III.50 Hz ~.

    ×
    Filtros
    Visualizar en modo Cuadrícula Visualizar en modo Listado
    anterior
    página de
    siguiente
    Las cookies nos permiten ofrecer nuestros servicios de forma más rápida y personalizada. Al acceder y continuar navegando en esta web acepta el uso de cookies. Para más información, lea nuestra Política de cookies
    Aceptar
    X

    Suscríbete!

    56.000 usuarios

    ya reciben toda la actualidad de la
    Arquitectura, Ingeniería y Construcción

    SUSCRÍBETE