×

Productos

    Abrir menu

    HIPLUS AIRE ACONDICIONADO, S.L.

    C. Masía Torrents, 2
    08800 VILANOVA I LA GELTRÚ (Barcelona)

    REQUEST A QUOTE/INFORMATION
    X
    NO IMAGE AVAILABLE

    2001.2 - Water chiller axial fan Krono XA - Cooling only

    2001.2EWXA
    0EUR
    SELECCIONAR PRODUCTO
    DESCRIPTION
    Water Chillers EWXA-EWXBA are compact units designed for its installation in the open air, on the ground or flat roof. It is provided with cooling load ready to installation.

    CABINET
    Freestanding base is built with profiles extremely rigid steel.The rest of the structure is made of galvanized steel, that provides and excellent covering. The color of finish set is RAL 1013.

    WATER COOLING EXCHANGER
    They are welded plates of stainless steel.They are well insulated and have an electrical heater to prevent freezing when the machine is stopped.

    COMPRESSORS
    EWXA-EWXBA range incorporates 2 compressors Scroll R410A assembled in tandem in an only refrigerant circuit. Compressor includes internal thermic protection of motor winds no requiring another motor protection. All the compressors equip an internal damping system and they are assembled on the chassis through dampers supports offering vibration-free operation. The compressors are fitted with crankcase heater for heating the oil and prevent accumulation of liquid refrigerant.

    OUTDOOR COILS
    Coils built with copper tubing without welding, they are expanded in aluminum fins.

    POWER SUPPLY
    Standard: 400.III+N.50Hz~.
    Consult on the availability for other power supplies, availability for different tension and frecuencies.

    MOTORFANS
    Prepared for to be in the open air, totally enclosed with permanent lubrification. They consist for aluminum blades designed to get a low sound level, inserted into the outer rotor of a high-efficiency motor with IP-54 protection and Class F insulation They have internal temperature sensors for protection and a outer grill for safety.

    EXPANSION DEVICES
    Thermostatic expansion valves incorporate.

    WATER CONNECTIONS
    Standard connections for both input and output water are thread gas diameter 2 .

    REFRIGERANT CIRCUIT
    Include the elements below:
    - 1 refrigerant circuitR410A
    - Outdoor coils with copper tubing and aluminum fins
    - Copper refrigerant lines ACR
    - Drier filter in liquid lines
    - Schrader Valves for service outlet in high and low pressure
    - 4-way reversible valve (Only Heat Pump models)
    - Expansion thermostatic system both cooling and heating
    - Suction Acumulator
    - Liquid vessel (Only Heat Pump models)
    - Non-return valve

    PROTECTIONS
    - High pressure pressostat (cut-off to 42 bar and manual reset)
    - Compressor crankcase heater
    - Antifreeze protection for water
    - Compressors control sequence
    - Differential Pressostat

    ELECTRONIC CONTROL
    The microprocessor manages the machine functioning and its alarms. Through probes it controls continously water temperature. Regulation by
    return temperature and optionally regulation by supply temperature.
    Electronic Control includes:
    - MODBUS Connection
    - Time programmer
    - Stop / Start up remote
    - Selection Cooling / Heating remote
    - Display temperatures water input / output
    - Display condensation and evaporation pressure
    - Alarms indication and remote control
    - Second setpoint (by models)
    ×
    Filtros
    Visualizar en modo Cuadrícula Visualizar en modo Listado
    anterior
    página de
    siguiente
    Las cookies nos permiten ofrecer nuestros servicios de forma más rápida y personalizada. Al acceder y continuar navegando en esta web acepta el uso de cookies. Para más información, lea nuestra Política de cookies
    Aceptar
    X

    Suscríbete!

    56.000 usuarios

    ya reciben toda la actualidad de la
    Arquitectura, Ingeniería y Construcción

    SUSCRÍBETE